Clostridium difficile TaqMan PCR Detection Kits
Register today to receive an exclusive 15% off* on your first order.
Features and Benefits
- Detection kits for Clostridium difficile
- Lyophilized format designed for room temperature shipping
- Available in TaqMan format for analysis
Clostridium difficile is rod-shaped, gram positive bacterium. It is the main causal agent of antibiotic-associated diarrhea and pseudomembranous colitis. The colonization of intestines by C. difficile is usually associated with the elimination of natural intestinal flora as a result of antibiotic application and is frequently reported in health care centers. While C. difficile infection could be severe and life-threatening, particularly among the elderly, many patients are asymptomatic making diagnosis challenging during outbreaks. The tradition method of detecting C. difficile infection is by cytotoxicity test of the toxin produced by the bacterium, but such protocols usually require extensive time before conclusion can be made.
Click to expand options
- Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
- Specific Primer and Probe mix for the pathogen/virus/viroid of interest
- Primer and Probe mix
- Positive and negative control to confirm the integrity of the kit reagents
- Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
- Nuclease-free water
- Can be used together with Norgen’s PCR Master Mix (#28007) or customer supplied master mix
For research use only and NOT intended for in vitro diagnostics.
Clostridium difficile is rod-shaped, gram positive bacterium. It is the main causal agent of antibiotic-associated diarrhea and pseudomembranous colitis. The colonization of intestines by C. difficile is usually associated with the elimination of natural intestinal flora as a result of antibiotic application and is frequently reported in health care centers. While C. difficile infection could be severe and life-threatening, particularly among the elderly, many patients are asymptomatic making diagnosis challenging during outbreaks. The tradition method of detecting C. difficile infection is by cytotoxicity test of the toxin produced by the bacterium, but such protocols usually require extensive time before conclusion can be made.
Click to expand options
- Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
- Specific Primer and Probe mix for the pathogen/virus/viroid of interest
- Primer and Probe mix
- Positive and negative control to confirm the integrity of the kit reagents
Norgen’s Clostridium difficile TaqMan PCR Lyophilized Kit is designed for the detection of Clostridium difficile specific DNA in a real-time PCR based on the use of TaqMan® technology. The lyophilized format is designed to ship the kit at ambient temperature.
Norgen’s Clostridium difficile TaqMan Lyophilized Probe/Primer and Control Set is designed for the detection of Clostridium difficile specific DNA in a real-time PCR based on the use of TaqMan® technology. The lyophilized format is designed to ship the kit at ambient temperature.
Details
Supporting Data
Figure 1. Example of HBV TaqMan PCR Positive result.
Both PCR signals above the baseline from FAM and HEX channel indicate the successful PCR.
Figure 2. Example of CMV TaqMan PCR Positive result.
Both PCR signals above the baseline from FAM and HEX channel indicate the successful PCR.
Figure 3. Example of HBV TaqMan PCR Negative result.
No target DNA was detected in FAM channel but amplification signal from HEX indicates the successful PCR.
Figure 4. Example of CMV TaqMan PCR Negative Result.
No target DNA was detected in FAM channel but amplification signal from HEX indicates the successful PCR..
Figure 5. Example of HBV TaqMan PCR inhibition result.
Example of TaqMan PCR inhibition result. No signal from both FAM and HEX channel was detected. It is suggested to repeat the sample preparation using recommended kit for DNA purification.
Figure 6. Example of CMV TaqMan PCR inhibition Result.
No signal from both FAM and HEX channel was detected. It is suggested to repeat the sample preparation using recommended kit for DNA purification.
Figure 7. Lyophilized qPCR kits produced virtually identical results to non-lyophilized kits in terms of Ct values.
Product Stability and Storage Conditions
- All kit components should be stored at -20°C upon arrival.
- Once reconstituted, repeated thawing and freezing (>2 times) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
- Each kit is provided with 4 tubes of 2X PCR Master Mix and each tube is enough to run 25 reactions. It is not necessary to reconstitute all Master Mix tubes at once. The Master Mix tubes can be reconstituted as and when needed.
- All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
| Component | Cat. TM37150 (100 preps) | Cat. TM37110 (100 preps) | TaqMan Probe Cat. DxTM37100 (24 rxns) | Cat. TM37150L (100 preps) | Cat. TM37110L (100 preps) |
|---|---|---|---|---|---|
| MDx TaqMan 2X PCR Master Mix | 2 x 700 μL | - | - | - | - |
| Clostridium difficile Primer & Probe Mix | 280 μL | 280 μL | - | - | - |
| Clostridium difficile Positive Control | 150 μL | 150 μL | - | - | - |
| Nuclease-Free Water (Negative Control) | 1.25 mL | 1.25 mL | - | 3 x 1.25 mL | 1 x 1.25 mL |
| Product Insert | 1 | 1 | 1 | 1 | 1 |
| MDx TaqMan 2X PCR Master Mix Dx | - | - | 550 µL | - | - |
| Clostridium difficile Primer & Probe Mix Dx | - | - | 2 x 70 µL | - | - |
| Clostridium difficile Positive Control Dx - 200,000 copies/μL | - | - | 50 µL | - | - |
| Nuclease-Free Water | - | - | 2 x 1.25 mL | - | - |
| MDx TaqMan 2X PCR Master Mix (Lyo) | - | - | - | 4 x 350 μL | - |
| Clostridium difficile Primer & Probe Mix (Lyo) | - | - | - | 280 μL | 280 μL |
| Clostridium difficile Positive Control (Lyo) | - | - | - | 150 μL | 150 μL |
Documentation
- in a timely manner that considers the person's accessibility needs due to disability; and
- at a cost that is no more than the regular cost charged to other persons