Soil DNA Isolation Maxi Kit
For research use only and NOT intended for in vitro diagnostics.
Soil DNA Isolation Maxi Kit
Register today to receive an exclusive 15% off* on your first order.
Supporting Data
Kit Specifications
|
|
Maximum Soil Input |
10 g
|
Type of Soil Processed |
All soil types
|
Maximum Column Binding Capacity |
1.5 mg
|
Average Yield from 10 g of soil* |
30-50 μg
|
Time to Complete 10 Purifications |
35 minutes (1 hour with OSR steps)
|
* Average yields will vary depending upon soil sample types
Storage Conditions and Product Stability
All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 1 year after the date of shipment.
Component | Cat. 62000 (10 preps) |
---|---|
Lysis Buffer G | 2 x 100 mL |
Lysis Additive A | 25 mL |
Binding Buffer I | 25 mL |
OSR Solution | 12 mL |
Buffer SK | 2 x 60 mL |
Wash Solution A | 1 x 18 mL |
Elution Buffer B | 30 mL |
Maxi Bead Tubes | 10 |
Humic Acid Removal Columns | 10 |
Maxi Spin Columns | 10 |
Elution Tubes | 10 |
Product Insert | 1 |
Documentation
FAQs
Maxi
Poor DNA recovery could be due to one or more of the following:
- Homogenization was incomplete.
Depending on the type of soil, further vortexing with the flat bed vortex or bead beater equipment may be required. However, it is not recommended to increase the vortex time to longer than 10 minutes at maximum speed.
- Lysis Additive A was not added to the lysate.
Ensure that the provided Lysis Additive A is added to separate humic acid and increase DNA yield.
- Ethanol was not added to the lysate.
Ensure that 5 mL of 96-100% ethanol is added to the lysate before binding to the column.
- Ethanol was not added to the Wash Solution A.
Ensure that the indicated amount of 96-100% ethanol is added to the supplied Wash Solution A prior to use.
If the DNA does not perform well in downstream applications, it may be due to one or more of the following:
- Eluted DNA sample is brown.
The elution contains high humic acids. Ensure that the OSR Solution was added to the clean lysate.
- DNA was not washed with the provided Buffer SK and Wash Solution A.
Traces of humic acids or salt from the binding step may remain in the sample if the column is not washed with the provided Buffer SK and Wash Solution A. Humic acids and salt may interfere with downstream applications and thus must be washed from the column.
- Ethanol carryover.
Ensure that the dry spin under the Column Wash procedure is performed in order to remove traces of ethanol prior to elution. Ethanol is known to interfere with many downstream applications.
- PCR reaction conditions need to be optimized.
Take steps to optimize the PCR conditions being used, including varying the amount of template (10 ng to 50 ng for 20 µL of PCR reaction is recommended), changing the source of Taq polymerase, looking into the primer design, and adjusting the annealing conditions.