ProteoSpin™ Total Protein Concentration, Detergent Clean-Up and Endotoxin Removal Kits
For research use only and NOT intended for in vitro diagnostics.
ProteoSpin™ Total Protein Concentration, Detergent Clean-Up and Endotoxin Removal Kits
Register today to receive an exclusive 15% off* on your first order.
Supporting Data
Kit Specifications
|
|
Maximum Protein Input |
200 ÎĽg
|
Maximum Column Volume Input |
600 ÎĽL
|
Molecular Weight of Recovered Proteins | No Molecular Weight cut-off |
Final Endotoxin Levels |
≤ 0.01 EU/μg protein
|
Protein Recovery |
90-95%
|
% Detergent Removal | 90-95% |
Detergents that can be Removed | Including Triton® X-100, CHAPS, NP-40 and Tween 20 |
Minimum Elution Volume |
50 ÎĽL
|
Time to Complete 10 Purifications |
20 minutes
|
Storage Conditions
All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years from the date of shipment.
Component | Cat. 22800 (25 preps) | Cat. 22200 (4 preps) |
---|---|---|
Binding Buffer J | 8 mL | 8 mL |
Binding Buffer N | 4 mL | 20 mL |
Wash Solution M | 50 mL | 130 mL |
Wash Solution CIP | 20 mL | 60 mL |
Wash Solution N | 30 mL | 130 mL |
Wash Solution NIP | 20 mL | 60 mL |
Elution Buffer G | 6 mL | 20 mL |
Endotoxin Removal Solution | 1.5 mL | 1.5 mL |
Protein Neutralizer EF | 2 mL | 2 mL |
Maxi Spin Columns (assembled with Collection Tubes) | - | 4 |
Mini Spin Columns | 25 | - |
Collection Tubes | 25 | - |
Maxi Spin Columns (assembled with Collection Tubes) | 4 | |
Elution Tubes (1.7 mL) | 25 | - |
Elution Tubes (50 mL) | 4 | - |
Product Insert | 1 | 1 |
Documentation
FAQs
Mini
The protein solution may not be flowing through the column due to one or more of the following:
- During the binding step for Protein Concentration and Detergent Clean-Up:
- Centrifugation speed was too low.
Check the centrifuge to ensure that it is capable of generating 5,200 x g (~8,000 RPM). Sufficient centrifugal force is required to move the liquid phase through the resin. Centrifugation speeds may be increased to 14,000 x g (~14,000 RPM), but this speed should not be exceeded.
- Inadequate spin time.
Spin an additional two minutes to ensure that the liquid is able to flow completely through the column.
- Cellular debris is present in the protein solution.
Prior to the sample preparation step, filter the sample with a 0.45 µM filter or spin down insoluble materials. Solid, insoluble materials can cause severe clogging problems.
- Protein solution is too viscous.
Dilute the protein solution and adjust the pH to either 3.5 - 4 or 7 with the appropriate Binding Buffer. Highly viscous materials due to high protein concentrations can slow down flow rate significantly.
- Protein solution is not completely dissolved.
Dissolve the sample in a larger amount of buffer. Solid, insoluble materials can cause clogging problems.
- Centrifugation speed was too low.
- For Endotoxin Removal:
- Centrifugation speed was too low.
Check the centrifuge to ensure that it is capable of generating 5,200 x g (~8,000 RPM). Sufficient centrifugal force is required to move the liquid phase through the resin. Centrifugation speeds may be increased to 14,000 x g (~14,000 RPM), but this speed should not be exceeded.
- Inadequate spin time.
Spin for an additional minute to ensure that the liquid is able to flow through the column.
- Cellular debris is present in the protein solution.
Prior to the sample preparation step, filter the sample with a 0.45 µM filter or spin down insoluble materials. Solid, insoluble materials can cause clogging problems.
- Centrifugation speed was too low.
Poor peptide/protein recovery could be due to one or more of the following:
- Incorrect pH adjustment of protein sample.
It is important that the proper amount of the appropriate Binding Buffer is added to the protein sample in order to adjust the pH to either 3.5 - 4 or 7 prior to loading onto the column.
- Incorrect procedure was used.
Ensure that the acidic protocol was used for total proteins and the basic protocol was used for basic proteins.
Poor peptide recovery for Endotoxin Removal could be due to one or more of the following:
- Input protein solution is very high in molarity.
The Binding Buffer J may not lower the pH of the protein solution sufficiently if the input protein solution has a very high molarity. Dilute the molarity of the input to < 50 mM with water. If the volume of the input amount is increased over the maximum 450 µL input, the sample can be split and processed using 2 columns.
- The appropriate amount of Binding Buffer J was not added.
Ensure that 20 µL of Binding Buffer J is added for every 500 µL of protein processed. The protein volume must not exceed 450 µL.
The eluted protein may be degraded due to one or more of the following:
A) For Protein Concentration and Detergent Clean-Up:
- Eluted protein solution was not neutralized.
Add 9.3 µL of Neutralizer to each 100 µL of eluted total proteins in order to adjust the pH to neutral. Some proteins are sensitive to high pH, such as the elution buffer at pH 12.5.
- Eluted protein was not neutralized quickly enough.
If eluted proteins are not used immediately, degradation will occur. We strongly suggest adding Neutralizer in order to lower the pH.
- Proteases may be present.
Use protease inhibitors during all steps of the Sample Preparation.
- Bacterial contamination of protein solution.
Prepare the protein sample with 0.015% sodium azide.
B) For Endotoxin Removal:
- Eluted protein was not neutralized.
Add 9.3 µL of Protein Neutralizer EF EF for every 100 µL of eluted protein in order to adjust the pH to neutral. Some proteins are sensitive to high pH, such as the Elution Buffer G.
- Bacterial contamination of protein solution.
The protein samples can be prepared with 0.015% sodium azide.
- Eluted protein was not neutralized quickly enough.
If the eluted protein is not neutralized immediately, degradation will occur. We strongly recommend adding Protein Neutralizer EF EF in order to lower the pH.
If the protein does not perform well in downstream applications for endotoxin removal, it may be because a different Elution Buffer was used. The provided Elution Buffer G has been optimized for endotoxin-free recoveries. The endotoxin-free properties of the eluted protein will be compromised if another Elution Buffer G is used. If a different Elution Buffer G other than the one provided is used, the buffer should also be checked for any components that may interfere with the application. Common components that are known to interfere are high salts, detergents, and other denaturants. Check the compatibility of your Elution Buffer with the intended use.
If endotoxin levels are high in the elution after the endotoxin removal protocol, it may be caused by:
- Using a different Elution Buffer.
The provided Elution Buffer G has been optimized for endotoxin-free recoveries. The endotoxin-free properties of the eluted protein will be compromised if another Elution Buffer is used. If a different Elution Buffer other than the one provided is used, the buffer should also be checked for endotoxin levels.
- Extremely high endotoxin levels in input protein.
Check the endotoxin levels of your protein input. The endotoxin levels of the eluted protein may be reduced significantly compared to the input.