HPV Low Risk (6/11) TaqMan PCR Kit
Register today to receive an exclusive 15% off* on your first order.
Overview
- Detection kits for Low Risk (6/11) HPV detection
- Available in TaqMan format for analysis.
Norgen’s HPV Low Risk (6/11) TaqMan PCR Kit is designed for the detection of HPV Low Risk (6/11) specific DNA in a real-time PCR based on the use of TaqMan technology. This kit is designed for research use only and not for use in diagnostic procedures. The detection of HPV Low Risk (6/11) specific DNA is based on TaqMan PCR providing a simple, reliable and rapid result for the detection of HPV Low Risk (6/11) infection. Norgen’s HPV Low Risk (6/11) TaqMan PCR Kit includes a PCR control to monitor for PCR inhibition, and to validate the quality of the sample and the detection result. The HPV Low Risk (6/11) TaqMan PCR Kit comprises Master Mix for the target and PCR control detection, Primer & Probe Mix, as well as a positive control and a negative control (nuclease-free water) to confirm the integrity of the kit reagents. The HPV Low Risk (6/11) TaqMan PCR Kit distinguishes between the detection of HPV 6 and HPV 11, allowing for clear and accurate results. HPV 11 detection is shown by amplification in the FAM channel. HPV 6 detection is shown by amplification in the Cy5 channel.
Norgen’s HPV Low Risk (6/11) TaqMan PCR Kit was developed and validated to be used with the following PCR instruments:
- Qiagen Rotor-Gene Q
- BioRad CFX96 TouchTM Real-Time PCR Detection System
- QuantStudioTM 7 Pro Real-Time PCR System
Click to expand options
100 reactions
- Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
- Specific Primer and Probe mix for the pathogen/virus/viroid of interest
- Primer and Probe mix
- Positive and negative control to confirm the integrity of the kit reagents
100 reactions
- Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
- Nuclease-free water
- Can be used together with Norgen’s PCR Master Mix (#28007) or customer supplied master mix
Details
Supporting Data
Component |
Product # TM32350 (100 preps)
|
MDx TaqMan 2X PCR Master Mix | 2 x 700 μL |
HPV Low Risk (6/11) Primer & Probe Mix | 280 μL |
HPV Low Risk (6/11) Positive Control | 150 μL |
Nuclease-Free Water (Negative control) | 1.25 mL |
Product Insert | 1 |
Storage Conditions and Product Stability
- All kit components should be stored at -20°C upon arrival.
- Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
- All kit components can be stored for 2 years after the date of production without showing any reduction in performance.