Vibrio cholerae TaqMan PCR Detection Kits

Cat. TM38550, TM38510
  • Professional Tech Support with Senior R&D Scientist
  • Fast and Flexible Ordering Options (online, email, or phone)
  • Volume Discounts Available on Large Quantity Orders*

*Inquire by phone or email for more information.


Vibrio cholerae TaqMan PCR Detection Kits

Cat. TM38550, TM38510
  • Detection kits for Vibrio cholerae
  • Available in TaqMan format for analysis
  • CE-IVD marked version available for in vitro diagnostic use

For research use only and NOT intended for in vitro diagnostics.

Want a discount?

Create your account to receive 15% off on your first purchase!

Vibrio cholerae TaqMan PCR Kit
(Cat. TM38550)
100 rxns
Vibrio cholerae TaqMan Probe/Primer and Control Set
(Cat. TM38510)
100 rxns

Product Format
Norgen Biotek offers kits in different standardized formats. You can view and compare kit components in the Components Table in the Product Overview section. For more information on format types, please visit our Format Information page.

Product Size

Kit Specifications

You have selected: Cat. TM38550

Storage Conditions and Product Stability
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.

All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.

You have selected: Cat. TM38510

Storage Conditions and Product Stability
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.

All kit components should be stored at -20°C upon arrival.

Supporting Data

Click for expanded view

Vibrio cholerae TaqMan PCR Detection Kits

Vibrio cholerae is a comma-shaped, gram-negative bacterium. It is the cause of cholera in humans, which affects the upper small intestine. Transmission of the disease is mainly through contaminated food or water. Human subjects affected by cholera exhibit severe watery diarrhea and vomiting, caused by the cholera toxin produced by the bacterium. Many cases of cholera are life-threatening, as diarrhea and associated vomiting can lead to rapid dehydration and electrolyte loss. Even with the extensive research on its epidemiology, cholera still affects over 5 million people per year worldwide.


Click to expand options
Vibrio cholerae TaqMan PCR Kit, 100 reactions
  • Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
  • Specific Primer and Probe mix for the pathogen/virus/viroid of interest
  • Primer and Probe mix
  • Positive and negative control to confirm the integrity of the kit reagents
Vibrio cholerae TaqMan PCR Probe/Primer Set and Controls, 100 reactions
  • Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
  • Nuclease-free water
  • Can be used together with Norgen’s PCR Master Mix (#28007) or customer supplied master mix

Supporting Data

Click for expanded view

Kit Specifications

You have selected: Cat. TM38550

Storage Conditions and Product Stability
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.

All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.

You have selected: Cat. TM38510

Storage Conditions and Product Stability
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.

All kit components should be stored at -20°C upon arrival.

Related Products