Plasma/Serum cfc-RNA Advanced Purification Kit
For research use only and NOT intended for in vitro diagnostics.
Plasma/Serum cfc-RNA Advanced Purification Kit
SKU
68200
Register today to receive an exclusive 15% off* on your first order.
Supporting Data
Kit Specifications
|
|
Minimum Plasma/Serum Input
|
1 mL |
Maximum Plasma/Serum Input
|
6 mL
|
Size of cfc-RNA Purified
|
All sizes, including miRNA and small RNA (< 200 nt)
|
Elution Volume |
25-50 µL
|
Time to Complete 10 Purifications |
45 minutes
|
Average Yields* | Variable depending on specimen |
*Please check page 5 in the product manual for the Plasma/Serum Average Yields and the Common RNA Quantification Methods.
Storage Conditions and Product Stability
All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment. The kit contains a ready-to-use Proteinase K, which is dissolved in a specially prepared storage buffer. The buffered Proteinase K is stable for up to 2 years after the date of shipment when stored at room temperature.
Kit Components | Cat. 68200 (50 preps) |
---|---|
Binding Buffer A | 20 mL |
Proteinase K | 6.5 mL |
Slurry E | 12.5 mL |
Lysis Buffer A | 130 mL |
Wash Solution A | 38 mL |
Elution Buffer C | 2 x 8 mL |
Elution Solution A | 20 mL |
Micro Spin Columns | 50 |
Mini Filter Spin Columns | 50 |
Collection Tubes | 100 |
Elution Tubes (1.7 mL) | 100 |
Product Insert | 1 |
Documentation
FAQs
A fixed speed centrifuge can be used, however reduced yields may be observed.
All centrifugation steps are performed at room temperature. Centrifugation at 4°C will not adversely affect kit performance.
Adding more or less than the specified volumes may reduce both the quality and the quantity of the purified RNA. Eluting your RNA in high volumes will increase the yield but will lower the concentration. Eluting in small volumes will increase the concentration but will lower the overall yield.
Your purified RNA will be contaminated with the Wash Solution A. This may reduce the quality of your purified RNA and will interfere with your downstream applications.
Yes, but it is recommended that the 2nd elution be in a smaller volume (50% of 1st Elution). It is also recommended to perform the 2nd elution into a separate elution tube to avoid diluting the 1st elution.
Varying the incubation time will result in a reduction in your RNA yields.
Plasma/Serum samples contain very little cfc-RNA. This varies from individual to individual. In order to increase the yield, the amount of Plasma/Serum input could be increased.
If a different Elution solution was used other than the one provided in the kit, the buffer should be checked for any components that may interfere with the application. Common components that are known to interfere are high salts (including EDTA), detergents and other denaturants. Check the compatibility of your Elution Buffer with the intended use.
You may need to do a DNase treatment to your isolated Plasma/Serum miRNA. It is recommended to
use Norgen’s RNase-Free DNase I Kit (Cat. 25710). Also please refer to the protocol for optional on column DNA removal outlined in Appendix A.
Yes, our plasma/serum RNA purification kits can be used to isolate RNA using blood samples preserved using Streck Cell-Free RNA Blood Collection Tubes.