Leukocyte RNA Purification Kits
For research use only and NOT intended for in vitro diagnostics.
Leukocyte RNA Purification Kits
Register today to receive an exclusive 15% off* on your first order.
Supporting Data
Kit Specifications
|
|
Maximum Column Binding Capacity |
Up to 50 μg RNA
|
Maximum Loading Volume |
650 μL
|
Size of RNA Purified |
All sizes, including small RNA <200 nt
|
Minimum Blood Input |
10 μL
|
Maximum Blood Input |
2 mL or 3 x 106 leukocytes
|
Time to Complete 10 Purifications |
40 minutes
|
Input Type |
Blood from Human, Hamster, Mouse, Rabbit, and Rat
|
Average Yield Human Blood (500 μL) Hamster Blood (100 μL) |
1.5 μg 2.5 μg |
Storage Conditions and Product Stability
All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment. The RBC Lysis Buffer should be stored at 4°C upon arrival.
Component | Cat. 21200 (50 preps) | Cat. 21250 (50 preps) | Cat. 37800 (2 x 96 preps) |
---|---|---|---|
RBC Lysis Buffer | 2 x 100 mL | 2 x 1 L | 2 x 90 mL |
Buffer RL | 30 mL | 30 mL | - |
Binding Solution | - | - | 2 x 40 mL |
Wash Solution A | 38 mL | 38 mL | - |
Wash Solution | - | - | 2 x 30 mL |
Elution Solution A | 6 mL | 6 mL | - |
Elution Solution | - | - | 2 x 20 mL |
Enzyme Incubation Buffer | - | 6 mL | 1 |
DNase I | - | 1 Vial | - |
Mini Spin Columns | 50 | - | - |
Lysate Homogenization Column | - | 50 | - |
Single Cell RNA Column | - | 50 | - |
RBC Lysis 96-Well Plate | - | - | 2 |
96-Well Filter Plate | - | - | 2 |
Adhesive Tape | - | - | 4 |
Collection Tubes | 50 | 100 | - |
96-Well Collection Plate | - | - | 2 |
Elution Tubes (1.7 mL) | 50 | 50 | - |
96-Well Elution Plate | - | - | 2 |
Product Insert | 1 | 1 | 1 |
Documentation
FAQs
Spin Column
- Incomplete lysis of leukocytes.
Ensure that the appropriate amount of Buffer RL was used to lyse the leukocyte pellet.
- Lysis of red blood cells was incomplete.
Ensure that the blood sample is collected with the appropriate amount of EDTA, which will prevent coagulation of the red blood cells and allow for proper lysis. Also check that the appropriate amount of RBC Lysis Buffer is added to the blood sample, and that it is mixed and incubated properly.
- Ethanol was not added to the lysate.
Ensure that 200 L of 96-100% ethanol is added to the lysate before binding to the column.
- Ethanol was not added to the Wash Solution A.
Ensure that 90 mL of 96 - 100% ethanol is added to the supplied Wash Solution A prior to use.
- An alternative elution solution was used.
It is recommended that the Elution Solution A supplied with this kit be used for maximum RNA recovery.
- The column has become clogged.
Do not exceed 2 mL of blood or 3 x 106
- Incomplete lysis of leukocytes.
Ensure that the appropriate amount of Buffer RL was used to lyse the leukocyte pellet.
- Lysis of red blood cells was incomplete.
Ensure that the blood sample is collected with the appropriate amount of EDTA, which will prevent coagulation of the red blood cells and allow for proper lysis. Improperly lysed red blood cells will clog the column.
- Amount of blood used exceeds kit specifications.
It is recommended that no more than 2 mL of blood or 3x 106 leukocytes be used in order to prevent possible clogging of the column.
- Centrifuge temperature is too low.
Ensure that the centrifuge remains at room temperature throughout the procedure. Temperatures below 15°C may cause precipitates to form that can cause the columns to clog.
- RNase contamination.
RNases may be introduced during the use of the kit. Ensure proper procedures are followed when working with RNA. Please refer to “Working with RNA” at the beginning of the protocol's user guide.
- Procedure not performed quickly enough.
In order to maintain the integrity of the RNA, it is important that the procedure be performed quickly. This is especially important for the Cell Lysate Preparation Step in the Animal Tissue protocol, since the RNA in animal tissues is not protected after harvesting until it is disrupted and homogenized.
- Improper storage of the purified RNA.
For short term storage RNA samples may be stored at -20°C for a few days. It is recommended that samples be stored at -70°C for longer term storage.
- Leukocyte pellets were too old.
Leukocyte pellets generated at the end of Step 1 may be stored for up to 2 weeks at -70°C and used in this procedure. It is not recommended that samples be frozen for longer than 2 weeks, as the integrity of the RNA may be compromised.
- RNA was not washed 3 times with the provided Wash Solution A.
Traces of salt from the binding step may remain in the sample if the well is not washed 3 times with Wash Solution A. Salt may interfere with downstream applications, and thus must be washed from the well.
- Ethanol carryover.
Ensure that the dry spin under Column Wash in the centrifugation protocol or the extended vacuum in the vacuum protocol is performed in order to remove traces of ethanol prior to elution. Ethanol is known to interfere with many downstream applications.